  MM4001 & MM4001iso rtd input transmitters description the MM4001 modules are used to provide an output voltage or current proportional to an rtd input signal. it is useful in measuring temperatures with a variety of rtd materials. the module utilizes a single constant- current source to excite the rtd and also has an accurate and stable leadwire compensation circuit for compensating 3-wire rtds against leadwire effects. the MM4001iso utilizes pulse width modulation to develop a pulse train with a duty cycle proportional to input signal amplitude. this pulse train is coupled through a pulse transformer where the duty cycle data is converted to a proportional dc level in the output circuit. options the following options are available on the MM4001 & MM4001iso: u all circuit boards conformal coated for protection against moisture. dc power inverter-isolated 12 v or 24 v dc power. controls two controls, zero and span, are accessible from the top of the module. calibration the MM4001 modules are shipped precalibrated, if there is a need to recalibrate, proceed as follows: refer to the instrument's label to determine your instrument's supply voltage and input and output ranges. refer to the "block diagram and pin connections" for pin connections. connect a precision decade resistance, potentiometer or rtd simulator to the input. to avoid errors due to the resistances of the connection wires, use a three-wire connection as shown in the ?block diagram and pin connections?. connect a precision dc voltage or current meter to the output. set the input resistance to the low end of the input range and adjust the zero control for the low-end output voltage or current. increase the input resistance to full scale and adjust the span control for the full-scale output. repeat until both readings are correct. case dimensions inches [mm] mounting the module is designed to plug into a standard 8 pin relay socket. (mp008) is a molded plastic socket that can be mounted on a flat surface or snapped into 2? inch wide pvc track (trk 48). a spring hold-down clip (clp1) is avail- able for installations where vibration may be a problem. a din-rail mounted socket (dmp008) is available for 35mm symmetrical rail. a killark hk series explosion-proof hous- ing with dome and 8-pin socket is available(hkb-hk2d-8). warranty the mighty module series of products carry a limited warranty of 10 + 5 years. in the event of a failure due to defective material or workmanship, during the 10 year period, the unit will be repaired or replaced at no charge. for a period of 5 years after the initial 10 year warranty, the unit will be repaired, if possible, for a cost of 10 % of the original purchase price. 1 2 http://
specifications rtd input 3-wire or 2-wire, 10 ohms to 2000 ohms input range select any range within rtd limit [min span 25f/14c (100f/55c with 10 ohms rtd)] excitation current 10 ohms 10 ma 100 ohms 5 ma 1000 ohms 0.5 ma 2000 ohms 0.2 ma output range voltage select any range from -10 v to +15 v, 10 ma max load (min span 0.2 v) current select any range from 0 to 50 ma max, >24 v compliance (1200 ohms max at 20 ma) 18 v compliance for iso option if fullscale output >20 ma open sensor output full scale accuracy 0.1% of span linearity (pt rtd, output vs temp) 0.5% of span, (temp 332f/0c) 0.15% of span, (temp <32f/0c) (others, output vs res) 0.01% of span temperature stability 0.04% of span per c common mode rejection 120 db,dc to 60 hz isolation (MM4001iso) output/input >500 megohms breakdown voltage >1000 vac rms output ripple (peak-to-peak) <0.1% of span breakdown, pwr/circuitry >1500 vac rms operating temperature 14f to 140f / -10c to 60c temperature stability 0.02% of span or 0.025c/c, whichever is greater power 115 vac 10%, 50 or 60 hz (2.5 w max) 230 vac 10%, 50 or 60 hz (2.5 w max) (dc power option) 24 vdc (limits 21 vdc to 32 vdc) (2.5 w max) isolation, dc power supply to input common: 10 megohms specifications are subject to change without notice. ? 2007 wilkerson instrument co., inc dwg#w102234b 3/07 3 4


▲Up To Search▲   

 
Price & Availability of MM4001

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X